Overview
The combination of the PRIMES FocusMonitor FM+ and the PowerMonitor enables comprehensive measurement of focused laser beam parameters and power in a single setup. In addition to power measurement, the system enables safe, long-term stable absorption of the entire laser radiation, completing the analysis of focused beams. This combination supports measurement of a wide range of processing lasers across multiple applications. From remote welding of copper-based alloys with high-power visible lasers to CO₂ flatbed cutting systems, virtually all areas of high-power laser material processing can be analyzed.
Combined datasheet specifications for the PowerMonitor and FocusMonitor FM+.
PowerMonitor xE2x80x94 Measurement Parameters
| Parameter | Specification |
| Models |
PM 48 / PM 100 / PM HP |
| Power Range |
PM 48: 0.3–8 kW | PM 100: 1–25 kW | PM HP: 3–150 kW |
| Wavelength Range |
PM 48/100: 450 nm, 515–530 nm, 800–1100 nm, 2000 nm, 10600 nm | PM HP: 1000–1100 nm |
| Irradiation Time |
Continuous (all) |
| Max. Power Density |
PM 48 (450, 515–532 nm): 10 kW/cm² | (800–1100 nm etc.): 15 kW/cm² | PM 100 (all): 5 kW/cm² | PM HP (1000–1100 nm): 20 kW/cm² |
| Divergence (Full Angle) |
Min. (convergent): −50 mrad | Max. (divergent): +160 mrad (PM 48) / +180 mrad (PM 100 & PM HP) |
PowerMonitor xE2x80x94 Device Parameters
| Parameter | Specification |
| Entrance Aperture |
PM 48: 48 mm | PM 100: 100 mm | PM HP: 90 mm |
| Accuracy |
PM 48: ±2.5% (450, 515–532 nm), ±2.0% (others) | PM 100: ±3.5% (450, 515–532 nm), ±3.0% (others) | PM HP: ±3.0% |
| Reproducibility |
±1% (all) |
| Time Constant |
15 s up to 99% of final value |
PowerMonitor xE2x80x94 Supply Data
| Parameter | Specification |
| Power Supply |
24 V ±5%, max. 0.5 A |
| Cooling Water Pressure (Min/Max) |
PM 48: 2/6 bar | PM 100: 1/4 bar | PM HP: 1/3 bar |
| Minimum Cooling Water Flow |
0.5 l/min per kW (all) |
| Minimum Cooling Water Flow (Interlock) |
PM 48: 4 l/min | PM 100: 8 l/min | PM HP: 25 l/min |
| Maximum Cooling Water Flow |
PM 48: 12 l/min | PM 100: 30 l/min | PM HP: 150 l/min |
| Water Pressure Drop |
PM HP: 2.1 bar at 75 l/min |
| Cooling Water Temperature Tin |
Dew point < Tin < 30°C |
| Stability of Cooling Water Temperature |
<1 K/min or <0.08 K/5 s |
| Compressed Air Pressure (Min/Max) |
2/4 bar |
| Purity Class |
ISO 8573-1:2010 [7:4:4] |
PowerMonitor xE2x80x94 Communication
| Parameter | Specification |
| Interfaces |
RS485 / USB / Interlock / Analog out |
PowerMonitor xE2x80x94 Dimensions and Weight
| Parameter | Specification |
| Dimensions (L × W × H) |
PM 48: 394 × 242 × 125 mm | PM 100: 580 × 330 × 215 mm | PM HP: 600 × 330 × 215 mm |
| Weight (Approx.) |
PM 48: 10 kg | PM 100: 44 kg | PM HP: 52 kg |
FocusMonitor FM+ xE2x80x94 Measurement Parameters
| Parameter | Specification |
| Models |
FM+ / FM+ HPD |
| Power Range |
FM+: 30–25,000 W | FM+ HPD: 30–25,000 W |
| Wavelength Range |
FM+: 400–12,000 nm | FM+ HPD: 515–545 nm / 1,000–1,100 nm |
| Beam Diameter |
FM+: 100–3,000 µm (up to 5,000 µm optionally) | FM+ HPD: 100–1,200 µm |
| Max. Power Density |
FM+ CO₂ (10.6 µm): 30 MW/cm² | Nd:YAG (1,000–1,100 nm): 10 MW/cm² | VIS (515–550 nm): 5 MW/cm² | Diode (800–1,000 nm): 1 MW/cm² | FM+ HPD: 50 MW/cm² |
| Max. Beam Divergence |
FM+ NIR high div.: 200 mrad | CO₂ high power: 240 mrad | Diode: 500 mrad | FM+ HPD: 120 mrad |
FocusMonitor FM+ xE2x80x94 Determined Parameters
| Parameter | Specification |
| Focus Position x, y, z |
Yes (FM+ / FM+ HPD) |
| Focus Radius x, y |
Yes (FM+ / FM+ HPD) |
| Beam Quality Factor M² |
Yes (FM+ / FM+ HPD) |
| Divergence Angle |
Yes (FM+ / FM+ HPD) |
| Power Density Distribution |
2D, 3D (FM+ / FM+ HPD) |
FocusMonitor FM+ xE2x80x94 Device Parameters
| Parameter | Specification |
| Measurement Window x-y |
FM+: 8 × 8 mm (12 × 12 mm optionally) | FM+ HPD: 8 × 8 mm |
| Working Range z |
120 mm (FM+ / FM+ HPD) |
| Resolution |
32 × 32 px to 1024 × 1024 px (FM+ / FM+ HPD) |
| Rotation Speed |
FM+: 1,875 / 3,750 / 7,500 min⁻¹ | FM+ HPD: 1,875 min⁻¹ |
| Linescan |
Yes (FM+ / FM+ HPD) |
FocusMonitor FM+ xE2x80x94 Supply Data
| Parameter | Specification |
| Power Supply |
24 V DC ±5%, max. 3.5 A (FM+ / FM+ HPD) |
| Inert Gas (Water and Oil Free) |
FM+: Helium, Nitrogen or Argon | FM+ HPD: Helium, Nitrogen, Argon, compressed air |
| Pressure Inert Gas |
typ. 0.5 bar (FM+ / FM+ HPD) |
FocusMonitor FM+ xE2x80x94 Communication
| Parameter | Specification |
| Interfaces |
Ethernet, RS485 (FM+ / FM+ HPD) |
FocusMonitor FM+ xE2x80x94 Dimensions and Weight
| Parameter | Specification |
| Dimensions (L × W × H) |
FM+: 280 × 242 × 218 mm | FM+ HPD: 318 × 242 × 218 mm |
| Weight (Approx.) |
8.5 kg (FM+ / FM+ HPD) |