Focus Measurement

FocusMonitor FMW+

The most versatile all-in-one solution for laser-based additive manufacturing machines.
Overview

The FocusMonitor FMW+ is specially designed for analyzing continuous irradiation, even at high beam powers. It is the compact version of the proven FocusMonitor FM+, with new electronics and an integrated absorber for powers up to 1,000 W. With no need for water cooling or gas supply, the FMW+ reliably determines the geometric dimensions of the focused laser beam as well as the focal point location in space, the beam parameter product and the beam quality factor M² — whether in R&D, machine commissioning or field service.

up to 1,000 W
Power Range
75–3,000 µm
Beam Diameter
90 kJ
Max. Energy per Measurement
Specifications
Datasheet specifications for the PRIMES FocusMonitor FMW+.
Measurement Parameters
ParameterSpecification
Power Range Up to 1,000 W
Wavelength Range 0.4–12 µm (depending on detector and measuring tip)
Beam Diameter 75–3,000 µm
Max. Energy per Measurement 90 kJ (up to 240 kJ on request)
Max. Power Density CO₂ (10,600 nm): 20 MW/cm² | Nd:YAG (1,000–1,100 nm): 5 MW/cm² | VIS (515–550 nm): 5 MW/cm²
Max. Beam Divergence (Depending on Tip) NIR high div: 200 mrad | CO₂ high power: 240 mrad
Determined Parameters
ParameterSpecification
Focus Position x, y, z Yes (with external z-axis)
Focus Radius x, y Yes (with external z-axis)
Beam Quality Factor M² Yes (with external z-axis)
Raw Beam Diameter with Focusing Element Yes (with external z-axis)
Divergence Angle Yes (with external z-axis)
Power Density Distribution 2D, 3D
Device Parameters
ParameterSpecification
Measurement Window Sizes 0.1 × 0.1 up to 8 × 8 mm
Resolution Up to 1,024 × 1,024 px
Rotation Speed 1,875 / 3,750 min⁻¹
Supply Data
ParameterSpecification
Power Supply 24 V DC ±5%, max. 1.8 A
Communication
ParameterSpecification
Interfaces Ethernet, OPC UA
Dimensions and Weight
ParameterSpecification
Dimensions (L × W × H) 185.5 × 153 × 237.5 mm (208.5 mm high with the carrying handle folded down)
Weight (Approx.) 8 kg
Features
Capabilities organized by functional domain.
Your Benefit
  • Installs in minutes thanks to its compact design and no need for additional media
  • Full integration into digital workflows via OPC UA
  • Measures all key beam parameters, from beam geometry and power density distribution to beam parameter product and the full caustic of the focused laser
  • Adaptable to all standard laser wavelengths used in additive manufacturing
  • Rugged, compact design with an integrated absorber for safe, reliable operation
How It Works

The FMW+ uses a micro-aperture measuring tip to sample a fraction of the beam, which is directed to a wavelength-dependent detector. As the fast-rotating tip moves across the beam, it scans the planar power density distribution with high spatial resolution. Unlike the FM+, the FMW+ has no z-axis of its own: the entire caustic is measured using the z-axis or build platform motion of the laser system, in accordance with ISO 11146. The integrated absorber safely takes up to 90 kJ — enough to measure a 400 W laser continuously for up to four minutes at full power.

Operation

The LaserDiagnosticsSoftware (LDS) enables semi-automatic or manual measurement of the beam distribution and determination of the beam position and beam dimensions, with fast data communication over Ethernet.

Measurement Sets

The detector and measuring tip can be changed by the user in a few minutes. The full system set includes the main device, two detectors, two measuring tips, a transport box and other accessories.

  • NIR: detector DFIG-PS+ (1–1.7 µm) with the NIR high div measuring tip, damage threshold up to 10 MW/cm²
  • CO₂: detector DFC+ (9–12 µm) with the CO₂ high power measuring tip, damage threshold up to 30 MW/cm²