Overview
The PRIMES PowerMonitor (PM) uses the same calorimetric principle as the CompactPowerMonitor. In contrast to the flat absorber in the CPM, the laser beam in the PowerMonitor is directed via a focusable mirror into a cylindrical absorber. A highly absorbent coating has been applied to the inside of the water-cooled absorber. The cylindrical absorber allows very high degrees of absorption with minimal back-reflection. This method is suited to very high powers. All parts that come into contact with the cooling water are manufactured from copper or brass. In this way stress corrosion is effectively prevented in the cooling cycle. A pneumatic closing device protects the PowerMonitor against dirt contamination.
PM 48: 0.3–8 kW / PM 100: 1–25 kW / PM HP: 3–150 kW
Power Range
±1%
Reproducibility
15 s up to 99% of final value
Time Constant
Specifications
PowerMonitor is offered in three models (PM 48 / PM 100 / PM HP); values below are listed per model where they differ.
Measurement Parameters
| Parameter | Specification |
|---|---|
| Models | PM 48 / PM 100 / PM HP |
| Power Range | PM 48: 0.3–8 kW | PM 100: 1–25 kW | PM HP: 3–150 kW |
| Wavelength Range | PM 48/100: 450 nm, 515–530 nm, 800–1100 nm, 2000 nm, 10600 nm | PM HP: 1000–1100 nm |
| Irradiation Time | Continuous (all) |
| Max. Power Density | PM 48 (450/515–532 nm): 10 kW/cm² | (800–1100 nm): 15 kW/cm² | PM 100 (all): 5 kW/cm² | PM HP (1000–1100 nm): 20 kW/cm² |
| Divergence (Full Angle) | Min: −50 mrad | Max: +160 mrad (PM 48) / +180 mrad (PM 100 & HP) |
Device Parameters
| Parameter | Specification |
|---|---|
| Entrance Aperture | PM 48: 48 mm | PM 100: 100 mm | PM HP: 90 mm |
| Accuracy | ±2.0–3.5% depending on model and wavelength |
| Reproducibility | ±1% (all) |
| Time Constant | 15 s up to 99% of final value |
Supply Data
| Parameter | Specification |
|---|---|
| Power Supply | 24 V ±5%, max. 0.5 A |
| Cooling Water Pressure (Min/Max) | PM 48: 2/6 bar | PM 100: 1/4 bar | PM HP: 1/3 bar |
| Minimum Cooling Water Flow | 0.5 l/min per kW (all) |
| Minimum Cooling Water Flow (Interlock) | PM 48: 4 l/min | PM 100: 8 l/min | PM HP: 25 l/min |
| Maximum Cooling Water Flow | PM 48: 12 l/min | PM 100: 30 l/min | PM HP: 150 l/min |
| Water Pressure Drop | PM HP: 2.1 bar at 75 l/min |
| Cooling Water Temperature Tin | Dew point < Tin < 30°C |
| Stability of Cooling Water Temperature | <1 K/min or <0.08 K/5 s |
| Compressed Air Pressure (Min/Max) | 2/4 bar |
| Compressed Air Purity Class | ISO 8573-1:2010 [7:4:4] |
Communication
| Parameter | Specification |
|---|---|
| Interfaces | RS485 / USB / Interlock / Analog out |
Dimensions and Weight
| Parameter | Specification |
|---|---|
| Dimensions (L × W × H) | PM 48: 394 × 242 × 125 mm | PM 100: 580 × 330 × 215 mm | PM HP: 600 × 330 × 215 mm |
| Weight (Approx.) | PM 48: 10 kg | PM 100: 44 kg | PM HP: 52 kg |